<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>treat complex PAD Archives - Cardio Flow, Inc.</title>
	<atom:link href="https://cardioflow.net/tag/treat-complex-pad/feed/" rel="self" type="application/rss+xml" />
	<link>https://cardioflow.net/tag/treat-complex-pad/</link>
	<description>A new orbital atherectomy technology</description>
	<lastBuildDate>Tue, 17 Sep 2024 13:54:31 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://cardioflow.net/wp-content/uploads/2020/12/cropped-CFI-favicon-600x600-02-32x32.jpg</url>
	<title>treat complex PAD Archives - Cardio Flow, Inc.</title>
	<link>https://cardioflow.net/tag/treat-complex-pad/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Cardio Flow Adds New 5 French 3-Sphere Driveshaft to its FreedomFlow Orbital Atherectomy Platform</title>
		<link>https://cardioflow.net/cardio-flow-adds-new-5-french-3-sphere-driveshaft-to-its-freedomflow-orbital-atherectomy-platform/</link>
		
		<dc:creator><![CDATA[Andrew Luce]]></dc:creator>
		<pubDate>Tue, 17 Sep 2024 06:00:28 +0000</pubDate>
				<category><![CDATA[FreedomFlow Orbital Atherectomy Platform]]></category>
		<category><![CDATA[5 French 3-Sphere]]></category>
		<category><![CDATA[Atherectomy]]></category>
		<category><![CDATA[Cardio Flow Inc.]]></category>
		<category><![CDATA[FreedomFlow]]></category>
		<category><![CDATA[peripheral artery disease (PAD)]]></category>
		<category><![CDATA[treat complex PAD]]></category>
		<category><![CDATA[vessel blockages]]></category>
		<guid isPermaLink="false">https://cardioflow.net/?p=13472</guid>

					<description><![CDATA[<p>The post <a href="https://cardioflow.net/cardio-flow-adds-new-5-french-3-sphere-driveshaft-to-its-freedomflow-orbital-atherectomy-platform/">Cardio Flow Adds New 5 French 3-Sphere Driveshaft to its FreedomFlow Orbital Atherectomy Platform</a> appeared first on <a href="https://cardioflow.net">Cardio Flow, Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid vc_custom_1654201298716 wpex-relative"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_ wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<a class="" data-lightbox="lightbox[rel-13472-3408513996]" href="https://cardioflow.net/wp-content/uploads/2024/07/CFI.Driveshafts_left.5Fr-3.5Fr-5.6Fr-5-1024x190.jpg" target="_self" class="vc_single_image-wrapper   vc_box_border_grey"><img width="1600" height="297" src="https://cardioflow.net/wp-content/uploads/2024/07/CFI.Driveshafts_left.5Fr-3.5Fr-5.6Fr-5.jpg" class="vc_single_image-img attachment-full" alt="" title="CFI.Driveshafts_left.5Fr-3.5Fr-5.6Fr-5" srcset="https://cardioflow.net/wp-content/uploads/2024/07/CFI.Driveshafts_left.5Fr-3.5Fr-5.6Fr-5.jpg 1600w, https://cardioflow.net/wp-content/uploads/2024/07/CFI.Driveshafts_left.5Fr-3.5Fr-5.6Fr-5-300x56.jpg 300w, https://cardioflow.net/wp-content/uploads/2024/07/CFI.Driveshafts_left.5Fr-3.5Fr-5.6Fr-5-1024x190.jpg 1024w, https://cardioflow.net/wp-content/uploads/2024/07/CFI.Driveshafts_left.5Fr-3.5Fr-5.6Fr-5-768x143.jpg 768w, https://cardioflow.net/wp-content/uploads/2024/07/CFI.Driveshafts_left.5Fr-3.5Fr-5.6Fr-5-1536x285.jpg 1536w" sizes="(max-width: 1600px) 100vw, 1600px" /></a>
		</figure>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid vc_custom_1654201298716 wpex-relative"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element vc_custom_1726507750133" >
		<div class="wpb_wrapper">
			<p>September 17, 2024—Cardio Flow, Inc. has added a new option to its <a href="/freedomflow/platform/">FreedomFlow® orbital atherectomy platform</a>. The new 5 French 3-sphere driveshaft adds a third option to the FreedomFlow platform, joining two 5-sphere driveshafts (5 French and 6 French) for the treatment of complex peripheral artery disease (PAD).</p>
<p>FreedomFlow’s diamond-coated spheres are designed to power through complex vessel blockages by harnessing the power of angular momentum—a rotational vortex that puts three to five diamond-coated spheres in constant contact with the vessel wall, whether advancing or retracting. This <a href="/freedomflow/modern-mechanism-of-action/">modern mechanism of action</a> gives physicians a highly efficient, effective, and flexible way to treat complex PAD in vessels ranging from 2 mm to 8 mm in diameter.</p>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid vc_custom_1725458053704 wpex-relative"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><div class="vc_row wpb_row vc_inner vc_row-fluid vc_custom_1725458255532 wpex-relative"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><figure class="vcex-image vcex-module wpex-text-right"><div class="vcex-image-inner wpex-relative wpex-inline-block vc_custom_1725458226778"><a href="https://cardioflow.net/wp-content/uploads/2024/07/CFI-Driveshafts.5Fr-3sphere-detail.jpg" class="wpex-lightbox"><img width="1500" height="250" src="https://cardioflow.net/wp-content/uploads/2024/07/CFI-Driveshafts.5Fr-3sphere-detail.jpg" class="vcex-image-img wpex-align-middle" alt="" loading="lazy" decoding="async" srcset="https://cardioflow.net/wp-content/uploads/2024/07/CFI-Driveshafts.5Fr-3sphere-detail.jpg 1500w, https://cardioflow.net/wp-content/uploads/2024/07/CFI-Driveshafts.5Fr-3sphere-detail-300x50.jpg 300w, https://cardioflow.net/wp-content/uploads/2024/07/CFI-Driveshafts.5Fr-3sphere-detail-1024x171.jpg 1024w, https://cardioflow.net/wp-content/uploads/2024/07/CFI-Driveshafts.5Fr-3sphere-detail-768x128.jpg 768w" sizes="auto, (max-width: 1500px) 100vw, 1500px" /></a></div></figure></div></div></div></div><div class="vc_row wpb_row vc_inner vc_row-fluid vc_custom_1725458265919 wpex-relative"><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_ wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img width="198" height="108" src="https://cardioflow.net/wp-content/uploads/2024/05/CFI.5Fr-3sphere-icon.jpg" class="vc_single_image-img attachment-full" alt="" title="CFI.5Fr-3sphere-icon" /></div>
		</figure>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-9"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>5 Fr 3-sphere is approximately 1.5 mm in diameter (0.062&#8243;) and treats vessels 2 mm &#8211; 4 mm</p>

		</div>
	</div>
</div></div></div></div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid vc_custom_1725457813762 wpex-relative"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><div class="vc_row wpb_row vc_inner vc_row-fluid wpex-relative"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><figure class="vcex-image vcex-module wpex-text-right"><div class="vcex-image-inner wpex-relative wpex-inline-block vc_custom_1725457959049"><a href="https://cardioflow.net/wp-content/uploads/2024/07/CFI-Driveshafts.5Fr-5sphere-detail.jpg" class="wpex-lightbox"><img width="1500" height="250" src="https://cardioflow.net/wp-content/uploads/2024/07/CFI-Driveshafts.5Fr-5sphere-detail.jpg" class="vcex-image-img wpex-align-middle" alt="" loading="lazy" decoding="async" srcset="https://cardioflow.net/wp-content/uploads/2024/07/CFI-Driveshafts.5Fr-5sphere-detail.jpg 1500w, https://cardioflow.net/wp-content/uploads/2024/07/CFI-Driveshafts.5Fr-5sphere-detail-300x50.jpg 300w, https://cardioflow.net/wp-content/uploads/2024/07/CFI-Driveshafts.5Fr-5sphere-detail-1024x171.jpg 1024w, https://cardioflow.net/wp-content/uploads/2024/07/CFI-Driveshafts.5Fr-5sphere-detail-768x128.jpg 768w" sizes="auto, (max-width: 1500px) 100vw, 1500px" /></a></div></figure></div></div></div></div><div class="vc_row wpb_row vc_inner vc_row-fluid wpex-relative"><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_ wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img width="198" height="108" src="https://cardioflow.net/wp-content/uploads/2024/05/CFI.5Fr-5sphere-icon.jpg" class="vc_single_image-img attachment-full" alt="" title="CFI.5Fr-5sphere-icon" /></div>
		</figure>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-9"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>5 Fr 5-sphere is approximately 1.5 mm in diameter (0.062”) and treats vessels 2 mm &#8211; 4 mm</p>

		</div>
	</div>
</div></div></div></div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid vc_custom_1725457824202 wpex-relative"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><div class="vc_row wpb_row vc_inner vc_row-fluid wpex-relative"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><figure class="vcex-image vcex-module wpex-text-right"><div class="vcex-image-inner wpex-relative wpex-inline-block vc_custom_1725457976843"><a href="https://cardioflow.net/wp-content/uploads/2024/07/CFI-Driveshafts.6Fr-5sphere-detail.jpg" class="wpex-lightbox"><img width="1500" height="250" src="https://cardioflow.net/wp-content/uploads/2024/07/CFI-Driveshafts.6Fr-5sphere-detail.jpg" class="vcex-image-img wpex-align-middle" alt="" loading="lazy" decoding="async" srcset="https://cardioflow.net/wp-content/uploads/2024/07/CFI-Driveshafts.6Fr-5sphere-detail.jpg 1500w, https://cardioflow.net/wp-content/uploads/2024/07/CFI-Driveshafts.6Fr-5sphere-detail-300x50.jpg 300w, https://cardioflow.net/wp-content/uploads/2024/07/CFI-Driveshafts.6Fr-5sphere-detail-1024x171.jpg 1024w, https://cardioflow.net/wp-content/uploads/2024/07/CFI-Driveshafts.6Fr-5sphere-detail-768x128.jpg 768w" sizes="auto, (max-width: 1500px) 100vw, 1500px" /></a></div></figure></div></div></div></div><div class="vc_row wpb_row vc_inner vc_row-fluid wpex-relative"><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_ wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img width="198" height="108" src="https://cardioflow.net/wp-content/uploads/2024/05/CFI.6Fr-5sphere-icon.jpg" class="vc_single_image-img attachment-full" alt="" title="CFI.6Fr-5sphere-icon" /></div>
		</figure>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-9"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>6 Fr 5-sphere is approximately 2.0 mm in diameter (0.082&#8243;) and treats vessels 4 mm &#8211; 8 mm</p>

		</div>
	</div>
</div></div></div></div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid wpex-relative"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Steve Crowell, Vice President of Sales and Marketing, noted,</p>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element vc_custom_1726322539560" >
		<div class="wpb_wrapper">
			<blockquote><p>
The sphere configuration in the new 5 French 3-sphere driveshaft offers physicians enhanced precision and flexibility for treating complex PAD. This advancement improves navigation through challenging anatomy, allowing for more effective treatments while ensuring control and ease of use. We’re excited to continue expanding our portfolio with advanced tools that improve patient outcomes.”
</p></blockquote>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element vc_custom_1726322551848" >
		<div class="wpb_wrapper">
			<p>Read more about FreedomFlow’s <a href="/freedomflow/modern-mechanism-of-action/">modern mechanism of action</a>.</p>

		</div>
	</div>
</div></div></div></div><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"></div></div></div>
</div><p>The post <a href="https://cardioflow.net/cardio-flow-adds-new-5-french-3-sphere-driveshaft-to-its-freedomflow-orbital-atherectomy-platform/">Cardio Flow Adds New 5 French 3-Sphere Driveshaft to its FreedomFlow Orbital Atherectomy Platform</a> appeared first on <a href="https://cardioflow.net">Cardio Flow, Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
